当前位置: 电磁阀 >> 电磁阀介绍 >> 进口双线圈二位三通电磁阀
进口二位三通电磁阀为活塞式结构,阀体安装无方向限制,平衡水平安装,本产品通常用在各种常温、中温、常压、中压等场合的纯净气体、液体、空气、水、瓦斯、煤气、油、蒸汽、制冷剂、热水的管路自动控制TheRetztwopositionthreewaysolenoidvalveisapistontypestructure,withnodirectionalrestrictionsonvalvebodyinstallationandbalancedhorizontalinstallation.Thisproductisusuallyusedforautomaticcontrolofpuregas,liquid,air,water,gas,gas,oil,steam,refrigerant,hotwaterpipelinesinvariousnormaltemperature,mediumtemperature,normalpressure,mediumpressureandotheroccasions
进口二位三通电磁阀工作原理-Workingprincipleofimportedtwo-positionthree-waysolenoidvalve
一进一出Onein,oneout
常闭式(2/3B):当线圈通电时,2通向1,1与3关闭。当线圈断电时,2与1关闭,1通向3Normallyclosed(2/3B):Whenthecoilisenergized,2leadsto1,1,and3close.Whenthecoilispoweredoff,2and1close,and1leadsto3
常开式(2/3K):当线圈通电时,3与1关闭,1通向2.当线圈断电时,3通向1,1与2关闭Normallyopen(2/3K):Whenthecoilispoweredon,3and1close,1leadsto2.Whenthecoilispoweredoff,3leadsto1,1,and2close
一进二出Onein,twoout
当线圈通电时,1通向2,1与3关闭。当线圈断电时,1与2关闭,1通向3Whenthecoilisenergized,1leadsto2,1,and3close.Whenthecoilispoweredoff,1and2close,and1leadsto3
二进一出Twoinandoneout
当线圈通电时,2通向1,3与1关闭。当线圈断电时,2与1关闭,3通向1Whenthecoilisenergized,2leadsto1,3,and1close.Whenthecoilispoweredoff,2and1close,and3leadsto1
注:二进一出的工作原理的电磁阀两进口端压力不相等时,需加止回阀Note:Whenthepressureatthetwoinletendsofthesolenoidvalvewiththeworkingprincipleoftwoinputsandoneoutputisnotequal,acheckvalveneedstobeadded
进口二位三通电磁阀结构特点--
动作响应快,换向和分流迅速
在真空负压和零压时都能正常工作
塑封线圈,提高阀的可靠性并能防水、防潮
独特设计、性能稳定、活塞结构、密封性好
配套线圈,不易烧毁
进口二位三通电磁阀选型参数--
产品规格:1/2-4"
阀体材质:黄铜、铸钢
介质温度:-40℃~+℃
适用压力:0~10MPa
防护性能:防水、防爆(DⅡCT5、ExdⅡCT5、ExmbⅡCT4、ExdⅡCT4)、防腐。
防护等级:IP67、IP65
阀芯材质:均为不锈钢
接线方式:接线座式、引线式、插头式
控制方式:常开、常闭
电源电压:DC24~V;AC36~V
连接方式:内螺纹、法兰
适用介质:气体、水、油品、蒸汽、燃气、腐蚀性流体等,小于50CSt(大于50时需定制)
泄漏量:零